🧊 Fridges and generic Modbus assets
In addition to charge points, meters, photovoltaic installations and batteries, Fuzz can follow two other types of assets:
- the fridge (Fridge): cooling unit or cold room, connected using Modbus or API;
- the generic Modbus asset (Generic modbus): any other Modbus device for which Fuzz has created a model.
These assets are created from the site Topology page (Create asset button, Asset section, then Fridge or Generic modbus). The full form is described in Add a fridge or a generic Modbus asset.
✅ Prerequisites
| Item | Required |
|---|---|
| Model | A Fuzz model for the device (Model field). There is no universal model: without a suitable model, request one from Fuzz support with the Modbus register table or the API documentation of the device |
| Hosting mode | Modbus: Edge or Hybrid. API: depending on the controller's network access to the API |
| Role | Administrator or Operator of the site |
🧊 Connect a fridge
For a fridge, depending on the model, Fuzz reads the temperatures, the thermal power, the coefficient of performance (COP), the setpoint and the temperature difference. These measurements are used for monitoring and alerts (for example a temperature that is too high, see Create and manage alert definitions).
The Fridge form has six steps: Fridge parameters, Fridge protocol, Phase mapping, Console, Metrics, Monitoring.
| Field | Meaning | Default |
|---|---|---|
| Fridge name | Name, unique on the site | — |
| Switchboard, Meter | Connection switchboard; dedicated meter if the fridge does not provide its electrical consumption | — |
| Maximum current (A) | Maximum current per phase | 16 |
| Correction factor | Percentage of the measured current taken into account in the available power calculation | 30 % |
| Protocol | Modbus or Api | Modbus |
With Modbus, fill in Model and the Modbus configuration card as for any Modbus asset (see Modbus assets). The Supported actions card shown for a fridge offers charge point actions (Set current (Smart charging), Start transaction…): they make no sense for a fridge, untick them all.
With Api, the Api Attributes Configuration card asks for:
| Field | Meaning |
|---|---|
| URL | Address from which Fuzz reads the measurements ("The url to read the metrics from") |
| Authentication Type | None (default), Basic Authentication (Username, Password), Open ID Connect (Oauth2) (Client ID, Client Secret, Oauth2 Token URL…) or Token based authentication (Token) |
| Properties | Advanced cases: values replaced in the URL. A property nodeId = 12345 replaces {nodeId} in the URL with 12345 |
🔧 Connect a generic Modbus asset
The Generic modbus asset is for Modbus devices that are not meters, inverters, batteries or charge points. What Fuzz reads depends entirely on the Model chosen, created by Fuzz for this device.
The form has six steps: Generic Modbus parameters, Generic modbus protocol, Phase mapping, Console, Metrics, Monitoring.
| Field | Meaning | Default |
|---|---|---|
| Name | Name, unique on the site | — |
| Switchboard, Meter | Connection switchboard, optional dedicated meter | — |
| Maximum current (A) | Maximum current per phase | 16 |
| Correction factor | Percentage of the measured current taken into account | 100 % |
| Model | Fuzz model of the device | — |
| Modbus configuration | See Modbus assets | — |
| Supported actions | Load forecast: leave unticked unless Fuzz says otherwise | Unticked |
Fuzz does not control a generic Modbus asset from smart charging: it measures it and can, if an alert definition provides for it, write a value to a register in reaction to an alert (Modbus Write Register remediation action, see Create and manage alert definitions).
🚫 Assets not available in self-service (wind turbines, generator sets, sensors…)
Generators, compressors, sensors and wind turbines cannot be created from the Console in self-service: they do not appear in the Create asset menu of the Topology page for installers and customers. If your project includes some (for example a backup generator to monitor, or a standalone temperature probe), contact Fuzz to discuss it before the works: do not declare them as a generic Modbus asset without Fuzz's agreement, because their measurements would not be interpreted correctly.
Virtual meters, on the other hand, are created in the Console by installers (Create asset > Virtual meter): see Virtual meter.